3 setting of manual jog (inching mode), Setting of manual jog (inching mode), Commissioning – Lenze ECSCPxxx User Manual

Page 121: Stop

Advertising
background image

Commissioning

Commissioning steps (overview)

Setting of manual jog (inching mode)

6

l

121

EDBCSXP064 EN 8.0

6.4.3

Setting of manual jog (inching mode)

(

Stop!

Machine parts can be damaged or destroyed!
The drive can travel into a mechanical limit during manual jog if

ƒ

no reference is known (status bit Stat1.HomePosAvailable = 0,

^ 161).

ƒ

no software limit positions are set (

237).

A manual jog requires the following commissioning steps:

Setting

Brief description

Detailed

information

1.

Set parameters for the
manual control.

Set the following codes in the GDC parameter menu in
Positioning

W Manual jog:

l

C3020 (traversing speed)

l

C3021 (acceleration)

l

C3022 (deceleration)

^ 173

2.

Save parameter set.

Set C0003 = 1.

3.

Enable controller.

l

Press the <F8> key in the GDC.

l

Green LED is lit continuously if X6/SI1 = HIGH,
X6/SI2 = HIGH, and the controller has been enabled via
the master control (PLC).

l

Green LED is blinking if X6/SI1 = HIGH and X6/SI2 = HIGH.
(No enable via master control!)

^ 241

4.

Set the direction of rotation
for manual control.

Set the following codes in the GDC parameter menu in Short
setup

W Operating mode:

l

C4010 = 3 (control interface C4040)

l

Control bits for CCW rotation (JogCCW):
– C4040/bit 12 = 1
– C4040/bit 13 = 0

ð Changeover to "ManualJog"state
– C4045/bit 2 = 1 (status bit Stat1.PStatManJog)

l

Control bits for CW rotation (JogCW):
– C4040/bit 12 = 0
– C4040/bit 13 = 1

ð Changeover to "ManualJog"state
– C4045/bit 2 = 1 (status bit Stat1.PStatManJog)

l

Control bits for manual jog stop:
– C4040/bit 12 = 0
– C4040/bit 13 = 0

ð Changeover to the "Stand−by" state
– C4045/Bit 0 = 1 (status bit Stat1.PStatStdBy)

Note:
In the case of C4040/bit 12 = 1 and bit 13 = 1, manual jog is
interrupted until one of the two bits is set to "0". The state
remains unchanged.

^ 158

^ 161

The motor rotates in the direction selected.

The settings for manual jog are now completed.

Proceed as follows:

ƒ

Set homing (

^ 122) when operating with a linear positioning axis

or

ƒ

Set relative continuous positioning (

^ 123) when operating with a continuous

positioning axis