Appendix

Code table

12

l

407

EDBCSXP064 EN 8.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C4023 Brk: N_Thresh

0.1 %

Speed threshold for brake
activation

^ 130

0.00

{0.01 %}

10.00

C4040 AppControl

0

Control word to the drive
Only active if C4010 = 3.

^ 158

0

{1}

65535

C4041 App−Rx−W2

0

Data word 2 to the drive
Only active if C4010 = 3.

−32767

{1}

32767

C4042 App−Rx−W3/4

0

Double data word 3/4 to the
drive
Only active if C4010 = 3.

−2147483647

{1}

2147483647

C4045 AppState 1

Status word 1 from the drive

l

Read only

^ 161

0

{1}

65535

C4046 AppState 2

Status word 2 from the drive

l

Read only

^ 161

0

{1}

65535

C4047 App−Tx−W2

0

Data word 2 from the drive

−32767

{1}

32767

C4048 App−Tx−W3

0

Data word 3 from the drive

−32767

{1}

32767

C4049 App−Tx−W3/4

0

Double data word 3/4 from the
drive

−2147483647

{1}

2147483647

C4050 PosProfSel

Number of the selected
positioning profile
Only display

0

{1}

15

C4052 PO: Ctrl (W1)

Currently effective control word
Ctrl1
Read only

0

{1}

65535

C4053 PO: W2

Currently effective VelDirect
value
Read only

−32767

{1}

32767

C4054 PO: W3/4

Currently effective PosDirect
value
Read only

−2147483647

{1}

2147483647

C4060 ES_NOffs

Only for "electrical shaft"
function: default value (in
increments) for
speed−proportional angular
trimming relating to
15000 rev./min.
Note: Only change value when
the controller is at standstill!

^ 235

−655360

{1 inc}

655360

Advertising