1 setting the stretch factor (c3097 / c3098), Setting the stretch factor (c3097 / c3098), Commissioning – Lenze ECSCPxxx User Manual

Page 212

Advertising
background image

Commissioning

Configuring the electrical shaft ("E−Shaft")
Setting the stretch factor (C3097 / C3098)

6

l

212

EDBCSXP064 EN 8.0

6.18.1

Setting the stretch factor (C3097 / C3098)

With the electrical shaft function, the setpoint speed can be adapted in the slave drive via
the stretch factor under C3097/C3098.

The required stretch factor results from the following factors:

ƒ

Mechanical ratio of the master drive in proportion to the mechanical ratio of the
slave drive (virtual gearbox).

ƒ

Required speed overshoot of the slave drive to increase the web tension.

The stretch factor is specified as numerator (C3097) / denominator (C3098). Permissible
value range:

ƒ

C3097: −32767 ... +32767 (negative values cause a reversal of direction of rotation).

ƒ

C3098: 1 ... 32760

The master value input (at X8, X4 or X1) is multiplied by the numerator (C3097) and divided
by the denominator (C3098):

Drehzahlsollwert

+ Leitwert @ C3097

C3098

)

Note!

ƒ

The machine parameters for the gearbox ratio (C1202/C1203,

^ 103) only

have an effect on positioning and have no impact on the "electrical shaft"
drive function.

ƒ

The stretch factor (C3097/C3098) can be changed during operation of the
"electrical shaft".

Advertising