background image

Electrical installation

Control terminals

Safe torque off

5

l

75

EDBCSXP064 EN 8.0

5.3.3.6

Example: Wiring with electronic safety switching device "Pilz PNOZ e1vp" for
Performance Level Pl

d

Pilz

774195

Pilz

774195

T1

T2

Pilz

PNOZ e1vp 10s

Not-Halt/

Emergency stop

24V DC

Start

S34

24

14

S22

S12

Y6

S11

S21

Y4

Y7

A2

S36

A1

Y32

ECSxS/P/M/A

QSP

SI1

X25

X6

SI2

S24

S0

BD1

BD2

B-

B+

GND

DI1

24V DC

H1

ECSXA034

Fig. 5−12

Example: Wiring with "Pilz PNOZ e1vp 10s" safety switching device

T1 Test key 1
T2 Test key 2

ƒ

The motor is shut down in accordance with stop category 1 of EN 60204 when the
safety function is requested.

ƒ

The delay time of the safety switching device and the quick stop deceleration time
have to be coordinated with the brake closing time.

ƒ

The diode−capacitor combination prevents the test pulses of the safety switching
device from disturbing the smooth running of the motor, as otherwise a short−time
inhibit of the controller cannot be ruled out. The diode−capacitor combination can be
procured from the company Pilz (Pilz order number: 774195) as a complete terminal
block.