Code table

12

l

400

EDBCSXP064 EN 8.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C3035 DwellTime

50

Dwell time after end of profile

^ 232

0

{1 ms}

65535 Time required from positioning

profile end (setpoint generator
has reached target position) to
the setting of status bit
Stat1.DwellTime = 1

C3036 BounceTime

0

Debounce time for touch probe
input

0

{0.001 ms}

65535

C3040 SW−LimPos

3600.0

Positive software limit position

^ 237

0.0000

{0.0001

units}

214000.0000

C3041 SW−LimNeg

−3600.0

Negative software limit position

^ 237

−214000.0000

{0.0001

units}

0.0000

C3042 SWLimCtrl

Mode

0

Mode of the software limit
position monitoring

0

Current setpoint position +
defined direction of movement

1

Current actual position

C3050 Act. position

Current position in increments
Read only

−2.147.483.647

{1 inc}

2.147.483.647

C3051 Current

position

Current position in units
Read only

−214000.0000

{0.0001

units}

214000.0000 The display is limited to +/−

214000.0000

C3052 Act. profile

l

Control bit
Ctrl1.ProfEnable = 1:
Number of the positioning
profile currently active or
executed last

l

Control bit
Ctrl1.ProfEnable = 1 or 0:
After cancelling the active
profile, the profile number 0
is displayed.

Read only

0

{1}

15

C3053 Current

velocity

Current speed in units/s
Read only

−214000.0000

{0.0001

units/s}

214000.0000

C3056 ActTargetPos

Current target position/distance
in increments (inc)

−2.147.483.647

{1 inc}

2.147.483.647

C3057 TargetPosReal

Current target position/distance
in units

−214000.0000

{0.0001

units}

214000.0000