Appendix, Code table – Lenze ECSCPxxx User Manual

Page 372

Advertising
background image

Appendix

Code table

12

l

372

EDBCSXP064 EN 8.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0367 Sync Rx ID

128

CAN sync receipt ID for CAN bus
interface X4

^ 280

1

{1}

256

C0368 Sync Tx Id

128

CAN Sync transmission ID for
CAN bus interface X4

^ 414

^ 278

1

{1}

256

C0369 SyNc Tx time

0

CAN sync transmission cycle for
CAN bus interface X4
A sync telegram with the
identifier of C0368 is sent with
the cycle time set.
ECSxP: The setting is effected
automatically depending on
C4062!

^ 279

0

{1 ms}

65000 0 = switched off

[C0370] SDO gateway

0

Activate address
gateway/remote
parameterisation

l

C0370

¹ 0: All code

write/read accesses are
redirected to the CAN node
with the CAN node address
set here.

l

The corresponding code is
accessed via parameter data
channel 1 of the target device.

l

C0370 = 0: remote
parameterisation is
deactivated

^ 289

0

{1}

63

C0371 Gateway Ch.

1

Selection of the gateway channel

^ 289

0

CAN

Use CAN bus interface X4

1

CAN−AUX

Use CAN bus interface X14

C0381 HeartProdTim

e

0

Heartbeat (slave):
HeartbeatProducerTime

l

Time interval for sending the
heartbeat message

l

Only relevant for setting
C0352 = 3.

0

{1 ms}

65535

C0382 GuardTime

0

Node Guarding (slave):
NodeGuardTime

l

Time interval of the status
inquiry of the master

l

Only relevant for setting
C0352 = 4.

^ 284

0

{1 ms}

65535

C0383 LifeTimeFact

0

Node Guarding (slave):
NodeLifeTime factor

l

Factor for the monitoring
time of NodeLifeTime

l

NodeLifeTime = C0383 x
C0382 (NodeGuardTime)

l

Only relevant for setting
C0352 = 4.

^ 284

0

{1}

255