158, status bits see, Commissioning – Lenze ECSCPxxx User Manual

Page 158

Advertising
background image

Commissioning

Process data to the axis module (control word Ctrl1 and setpoints)

6

l

158

EDBCSXP064 EN 8.0

6.11

Process data to the axis module (control word Ctrl1 and setpoints)

Process data is transmitted cyclically to the drive via the control interface set under C4010
with a data width of 8 bytes or 4 words.

The telegram structure of the 8 byte process data to the drive is the same for all selectable
control interfaces. In addition to the control word Ctrl1 (Word 1), Word 2, Word 3 and Word
4 are available for setpoints.

Control bit 15 of the control word Ctrl1 serves to set the assignment of the words 2 ... 4.

Assignment of the process data to the drive:

Word 1

Word 2

DWord (word 3 + word 4)

LOW byte HIGH byte LOW byte HIGH byte

LOW word

HIGH word

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Ctrl1.Bit15 = 0

Control word

Ctrl1

rx_par1

rx_par2

rx_par3

Ctrl1.Bit15 = 1

VelDirect

PosDirect