Monitoring functions

Fault responses

9

l

292

EDBCSXP064 EN 8.0

9.1

Fault responses

Response

ð Consequence

Display

Keypad XT

RDY

IMP

Fail

TRIP

o

n

n

TRIP active:

ð The power outputs U, V, W are switched to high resistance.

ð The drive is coasting (no control).

TRIP reset:

ð The drive decelerates to its setpoint within the set deceleration
times.

Message

Danger!
The drive restarts automatically if the message is removed.

o

n

n

Message active:

ð The power outputs U, V, W are switched to high resistance.

£ 0.5 s ð The drive is coasting (no control).
> 0.5 s

ð The drive is coasting (due to internal controller inhibit). If
necessary, restart program.

Message reset:

ð The drive runs to its setpoint with the maximum torque.

FAIL−QSP

ð The drive is decelerated to standstill within the quick stop
deceleration time (C0105).

˘

˘

n

Warning

STOP!
The drive can be destroyed due to deactivated monitoring
functions.

n

o

n

ð The failure merely is displayed, the drive runs on in a controlled
manner.

Off

STOP!
The drive can be destroyed due to deactivated monitoring
functions.

˘

˘

˘

ð There is no response to the failure.

o = off

n = on

Responses (

¶ 292) of monitoring functions can be parameterised partly via codes ˘ in the

GDC parameter menu under Monitoring.