Device status

The status bits 8 ... 11 in C0150 display the binary−coded device status of the axis module:

Status bit 11

Status bit 10

Status bit 9

Status bit 8

Description

0

0

0

0

Initialisation after connecting the
supply voltage

0

0

0

1

Switch−on inhibit / restart
protection active (C0142 = 0)

0

0

1

1

Controller inhibited

0

1

1

0

Controller enabled

0

1

1

1

A monitoring function returns a
"message".

1

0

0

0

A monitoring function returns a
"TRIP".

1

0

1

0

A monitoring function returns a
"FAIL−QSP".

0 = FALSE

1 = TRUE

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0150 Status word

0

Device status word for
networking via automation
interface (AIF)
Read only

^ 163

0

{1}

65535 Controller evaluates information

as 16 bits (binary−coded)

Bit 0

Not assigned

Bit 1

Pulse inhibit (IMP)

Bit2

Not assigned

Bit3

Not assigned

Bit4

Not assigned

Bit5

Not assigned

Bit 6

n = 0

Bit 7

Controller inhibit (CINH)

Bit 8

Device status bit 1

Bit 9

Device status bit 2

Bit10

Device status bit 3

Bit11

Device status bit 4

Bit12

Warning

Bit13

Message

Bit14

Not assigned

Bit15

Not assigned