Commissioning – Lenze ECSCPxxx User Manual

Page 213

Advertising
background image

Commissioning

Configuring the electrical shaft ("E−Shaft")

Setting the stretch factor (C3097 / C3098)

6

l

213

EDBCSXP064 EN 8.0

Formulas for setting the stretch factor

Requirements:

ƒ

The circumferential speeds of both rolls are to be the same.

ƒ

Both rolls have the same diameter so that they must have the same speed too.

roll 1

roll 2

ratio i1

ratio i2

motor 1

(Master)

motor 2
(Slave)

stretch

factor

ECSXP004

Fig. 6−50

Electrical shaft: Master and slave roller drives affect the same web.

roll 1

Roll 1

roll 2

Roll 2

ratio i1

Mechanical gearbox ratio − master

ratio i2

Mechanical gearbox ratio − slave

stretch factor

Stretch factor

Requirement: Synchronism of the rolls

n

roll 1

+ n

roll 2

n

motor 1

i1

+

n

motor 2

i2

stretchfactor

+

n

motor 2

n

motor 1

+ i2

i1

stretch factor

+ i2

i1

+ C3097

C3098

Different roll diameters (d1, d2) must be considered for the stretch factor as follows:

stretch factor

+ i2

i1

@ d1

d2

+ C3097

C3098