Appendix – Lenze ECSCPxxx User Manual

Page 388

Advertising
background image

Appendix

Code table

12

l

388

EDBCSXP064 EN 8.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C2102 Task switch

0

Change−over:
System task

àcycl. task (PLC)

0

Time slice

No change−over

1

Time slice + end of PLC_PRG

2

Time slice + end of PLC_PRG + end of
system task

C2104 PLC Autorun

(Posi & Shaft)

1

Automatic start of PLC program
after power−up

0

Off

1

On

C2106 Downl.protect

0

Write protection of PLC program

0

Inactive

1

Active

2

Reserved

C2108 PLC run/stop

(Posi & Shaft)

2

{1}

PLC programcontrol

0

No function

1

Run

2

Stop

3

Reset

C2111 GDC Id

27012006132510 =

l

Date (day.month.year): 27.01.2006

l

Time (h:min:sec): 13:25:10

Creation date of PLC program
Read only

C2113 PLC Prog

Name

Name of PLC program
Read only

C2115 T−Fkt Credit

0

Number of technology units

C2116 CreditPinCode

0

Code for technology units if
service is required (please
consult Lenze)

0

{1}

4294967295

C2117 Full Credit

0

Service code

C2118 ParWriteChan

.

0

CAN object for L_ParRead and
L_ParWrite
(byComChannel = 10)

^ 289

0

Unused PDO channel free for
reconfiguration
(CAN1...3_IN/CAN1...3_OUT)

1

Parameter data channel 2

C2120 AIF: Control

0

AIF−CAN: control word

0

{1}

255 Binary interpretation reflects bit

states

0

No command

Note: The MSB (bit 7) of the
control word automatically
changes its state with every
access to the code. Observe this
when interpreting the data!

1

Read XCAN codes + reinitialisation

2

Read XCAN code

10

Read XCAN C2356/1 ... 4

11

Read XCAN C2357

12

Read XCAN C2375

13

Read XCAN C2376 ... C2378

14

Read XCAN C2382

255

Not assigned