Code table

12

l

359

EDBCSXP064 EN 8.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0093 Drive ident

Device identification of the ECS
axis module
Read only

0

Defective power section

1

No power section recognised

4

ECSxS/P/M/A004C4

8

ECSxS/P/M/A008C4

16

ECSxS/P/M/A016C4

32

ECSxS/P/M/A032C4

48

ECSxS/P/M/A048C4

64

ECSxS/P/M/A064C4

65

ECSxS/P/M/A064C2

C0094 Password

0

Keypad password
Parameter access protection for
the keypad

0

{1}

9999 When the password is activated,

only the codes of the user menu
(C0517) can be accessed. Further
possible selections: see C0096

0 = no password

[C0095] Rotor pos adj

0

Activation of rotor position
adjustment for automatic
determination of the rotor
displacement angle.
C0058 displays the determined
rotor displacement angle (offset
angle).

^ 249

0

Inactive

1

Active

C0096

Extended password protection
for bus systems with activated
password (C0094)
All codes in the user menu can be
accessed.

1 AIF/CAN prot.

0

No access protection

AIF access protection

2 AIF/CAN prot.

0

No access protection

CAN access protection

0

No access protection

Full access

1

Read protection

Reading not possible

2

Write protection

Writing not possible

3

Read/write protection

Reading and writing not possible

C0097 DIS:Lt−Ident

0

Power stage identification

0

{1}

255

C0098 Set position

0

Home position of encoder

−2147483647

{1 inc}

2147483647

C0099 S/W version

Firmware version
Read only

0,0

{0,1}

25,5

C0105 QSP Tif

0.0

Deceleration time for quick stop
(QSP)

^ 243

0.000

{0.001 s}

999.999 Relating to speed variation n

max

(C0011) ...0 rev./min.