Example: Wiring with electromechanical safety switching device "Siemens 3TK2827"
for Performance Level Pl

d

Start

Not-Halt/ Emergency stop

Siemens 3TK2827

Y22

Y

21

Y

12

Y

11

58

57

48

47

14

13

Y

10

Y34

Y33

24V DC

T1

T2

24

23

A1

A2

ECSxS/P/M/A

QSP

SI1

X25

X6

SI2

S24

S0

BD1

BD2

B-

B+

GND

DI1

H1

ECSXA035

Fig. 5−13

Example: Wiring with "Siemens 3TK2827" safety switching device

T1 Test key 1
T2 Test key 2

ƒ

The motor is shut down in accordance with stop category 1 of EN 60204 when the
safety function is requested.

ƒ

The delay time of the safety switching device and the quick stop deceleration time
have to be coordinated with the brake closing time.

Description of the function

ƒ

The "Siemens 3TK2827" safety switching device has a two−channel effect on the
controller. In the case of an emergency stop request the two channels (terminals 48
and 58) become deenergised. The safety switching device monitors the diagnostic
output of the controller.

ƒ

If the "safe torque off" safety function is activated, output X6/SO is at HIGH level.
This state is shown to the operator by means of the indicator light H1. Afterwards
switch−on is possible again using the Start pushbutton.

ƒ

At least once a year a manual test has to be carried out to verify the independence
and cutout ability of the two disconnecting paths.