Monitoring functions, Overview of monitoring functions – Lenze ECSCPxxx User Manual

Page 295

Advertising
background image

Monitoring

functions

Overview of monitoring functions

9

l

295

EDBCSXP064

EN 8.0

Possible fault responses

l Lenze setting

ü Can be set

Monitoring

Off

Fail−QSP

Warning

Message

TRIP

Code

Source

Description

Fault message

x085

Sd5

Master current value encoder error on analog input X6/AI+, AI− (C0034 = 1)

MCTRL

C0598

ь

ь

l

x087

Sd7

Absolute value encoder initialisation error at X8

MCTRL

l

x088

Sd8

Sin&cos signal fault at X8

MCTRL

C0580

ü

l

x089

PL

Fault during rotor position adjustment

MCTRL

l

Speed

x190

nErr

Speed control error (monitoring window C0576)

MCTRL

C0579

ь

ь

ь

ь

l

x200

NMAX

Max. system speed (C0596) has been exceeded.

MCTRL

C0607

l

ь

ь

Float error

0209

float Sys−T

Float error in system task (ID 0)

Internal

l

ь

ь

2)

0210

float Cycl.−T Float error in cyclic task (PLC_PRG ID 1)

Internal

l

ь

ь

2)

0211

float Task1

Float error in task 1 (ID 2)

Internal

l

ь

ь

2)

...

...

...

0218

float Task8

Float error in task 8 (ID 9)

Time−out / overflow

0105

H05

Internal fault (memory)

Internal

l

x108

H08

Extension board not connected properly or not supported by program.

Internal

l

0201

overrun
Task1

Time−out in task 1 (ID 2)

Internal

l

ь

ь

2)

...

...

...

0208

overrun
Task8

Time−out in task 8 (ID 9)

0219

overrun
Cycl.−T

Time−out in cyclic task (PLC_PRG, ID 1)

Internal

l

ь

ь

2)

0220

noT−Fkt
Credit

Not enough technology units available in the PLC.

Internal

l

0230

No program No PLC program loaded in the PLC.

Internal

l

0231

Unallowed
Lib

You have called the library function in the PLC program. This function is not
supported.

Internal

l

x232

NoCamData Motion profiles (cam data) are not available.

Internal

l

x240

ovrTrans
Queue

Overflow of transmit request memory

Free CAN
objects

C0608

l

ь

ь

ь

ь

x241

ovr Receive

Too many receive telegrams

Free CAN
objects

C0609

l

ü

Parameter setting
x: 0 = TRIP, 1 = message, 2 = warning, 3 = FAIL−QSP

1)

Adjustable in the DDS under Project

W Exceptional handling

2)

For ECSxA... only

Advertising
This manual is related to the following products: