21 defining the window for standstill message, Commissioning – Lenze ECSCPxxx User Manual

Page 231

Advertising
background image

Commissioning

Defining the window for standstill message

6

l

231

EDBCSXP064 EN 8.0

6.21

Defining the window for standstill message

The standstill message is activated if the actual speed falls below a certain speed limit
value (independent of the direction of rotation). The limit value (C3017) and hysteresis
(C3018) can be set in the GDC parameter menu under Positioning

W Machine parameters.

Function sequence

ƒ

If the current speed falls below the speed threshold (C3017), status bit Stat2.Nmin is
set to 1.

ƒ

Only when the current speed exceeds the value of C3017 + C3018 again, status bit
Stat2.Nmin is reset to "0".

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C3017 Lim.n=0−Flag

0.10

Limit value for speed, (n

min

signal)

^ 231

0.01

{0.01 %}

100.00 If the value falls below the limit

value, the status bit Stat2.Nmin
is set to 1.

C3018 Hyst.n=0−Flag

0.10

Hysteresis for speed (n

min

signal)

^ 231

0.00

{0.01 %}

100.00