Commissioning

Setting of the feedback system for position and speed control
TTL/SinCos encoder as position encoder and resolver as speed encoder

6

l

142

EDBCSXP064 EN 8.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

[C0095] Rotor pos adj

0

Activation of rotor position
adjustment for automatic
determination of the rotor
displacement angle.
C0058 displays the determined
rotor displacement angle (offset
angle).

^ 249

0

Inactive

1

Active

C0414 DIS: ResQual.

Resolver modulation
Quality of the resolver excitation
amplitude set under C0416
(recommendation: 0.5 ... 1.2;
ideal 1.0)

^ 133

0.00

{0.01}

1,60

[C0416] Resolver adj.

5

Resolver excitation amplitude

^ 133

0

100 %

1

80 %

2

68 %

3

58 %

4

50 %

5

45 %

6

40 %

7

37 %

[C0417] Resolver cor.

0

Resolver adjustment

^ 257

0

Ready

1

Start adjustment

2

Loading default values