Commissioning

Process data from the axis module (status words and actual values)
Monitor data words from the controller (tx_par1 und tx_par2)

6

l

164

EDBCSXP064 EN 8.0

6.12.3

Monitor data words from the controller (tx_par1 und tx_par2)

The monitor data words "tx_par1" and "tx_par2" can be assigned with various display
values via control bits in the control word Ctrl1:

ƒ

Control bit 0 ("Ctrl1−Func1")

ƒ

Control bit 1 ("Ctrl1−Func2")

ƒ

Control bit 2 ("Ctrl1−Func4")

The following assignment of the monitor data words can be set via the control bits:

Control bits 0..2
in the control
word Ctrl1
[binary]

Monitor data word

tx_par1

tx_par2

...000

Actual position (2

16

== 1 position encoder revolution)

...001

FollowErr (2

16

== 1 position encoder revolution)

...010

Actual speed value n

act

Scaling: 2

14

== C0011 (maximum speed)

Actual torque M

act

Scaling: 2

14

== C0057 (calculated maximum

torque)

...011

Not assigned

...100

Not assigned

...101

Fault number

DCTRL_wStat (C0150)
Bit assignment: See code list

...110

Profile generator state (C3066)
Bit assignment: See code list

Not assigned

...111

AIn1

DigIn

Bit assignment

l

Bits 0 ... 12: image of analog input

l

Bits 13, 14, 15: 0 (no function)

Bit assignment

l

Bit 0 (x6/DI1): image of digital input 1

l

Bit 1 (X6/DI2): image of digital input 2

l

Bit 2 (X6/DI3): image of digital input 3

l

Bit 3 (x6/DI4): image of digital input 4

l

Bits 4 ... 15: 0 (no function)