Electrical installation – Lenze ECSCPxxx User Manual

Page 67

Advertising
background image

Electrical installation

Control terminals

5

l

67

EDBCSXP064 EN 8.0

Assignment of the plug connectors

Plug connector X6

Terminal

Function

Electrical data

X6/+24

Low−voltage supply of the control electronics

20 ... 30 V DC, 0. A (max. 1 A)
for starting current of 24 V:
max. 2 A for 50 ms

X6/GND

Reference potential of low−voltage supply

X6/DO1

Digital output 1

24 V DC, 0.7 A (max. 1.4 A)
short−circuit−proof

X6/DI1

Digital input 1

LOW:
−3 ... +5 V;
−3 ... +1.5 mA
HIGH:
+15 ... +30 V;
+2 ... +15 mA
Input current at 24 V DC:
8 mA per input

X6/DI2

Digital input 2

X6/DI3

Digital input 3

X6/DI4

Digital input 4

X6/AI+

Analog input +

Adjustable with jumper strip X3:
−10 ... +10 V, max. 2 mA
−20 ... +20 mA
Resolution: 11 bits + sign

X6/AI−

Analog input −

X6/AG

Reference potential of analog input (internal
ground)

X6/B+

Brake supply +

23 ... 30 V DC
max. 1.5 A
Set brake voltage so that the permissible
voltage at the brake is not under−run or
exceeded ˘ otherwise malfunction or
destruction!

X6/B−

Brake supply −

X6/S24

Connection of "safe torque off" (formerly "safe
standstill")

^ 70

X6/SO

X6/SI1

X6/SI2

Cable cross−sections and screw−tightening torques

Cable type

Wire end ferrule

Cable cross−section

Tightening torque

Stripping length

Flexible

Without wire end
ferrule

0.08 ... 1.5 mm

2

(AWG 28 ... 16)

0.22 ... 0.25 Nm

(1.95 ... 2.2 lb−in)

5 mm for screw
connection

9 mm for spring
connection

With insulated wire
end ferrule

0.25 ... 0.5 mm

2

(AWG 22 ... 20)

We recommend to use control cables with a cable cross−section of 0.25 mm