Appendix, Code table – Lenze ECSCPxxx User Manual

Page 406

Advertising
background image

Appendix

Code table

12

l

406

EDBCSXP064 EN 8.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

[C4011] DigIn_map

0

Assignment of the digital inputs
X6/DI1 ... DI4
Acceptance only if the controller
is inhibited (status word
Stat1.Imp = 1).

^ 168

DI1

DI2

DI3

DI4

Ix: Input x is not assigned with a
function.
JogCW: Manual jog CW
JogCCW: Manual jog CCW
Ln: Limit switch in negative
direction
Lp: Limit switch in positive
direction
PNo1: Selection of positioning
profile bit 2

0

PNo2: Selection of positioning
profile bit 2

1

PNo4: Selection of positioning
profile bit 2

2

PNo8: Selection of positioning
profile bit 2

3

Penb: Positioning profile
activated (enable)
Qsp: Quick stop (QSP)
R: TRIP−RESET
Ref: Reference switch
TP: Touch probe input

0

Ln Ref TP Lp

1

PNo1 PNo2 PNo4 PNo8

2

PNo1 PNo2 PNo4 PEnb

3

PNo1 PNo2 R

PEnb

4

Qsp JogCW

Tp JogCCW

5

I1

I2 TP I4

6

Ln

Qsp

Penb

Lp

7

PNo1

PNo2

TP

Penb

8

PNo1

PNo2

Ref

Penb

9

Ln

PNo1

PNo2

Lp

10

Ln

JogCW

JogCCW Lp

11

Ln

Ref

Penb

Lp

12

Ln

Ref

Qsp

Lp

13

Ln

Qsp

TP

Lp

[C4012] DigOut_map

0

Assignment of digital output
X6/DO1
Acceptance only if the controller
is inhibited (status word
Stat1.Imp = 1).

^ 168

0

RDY

Rdy: Drive is ready for operation.

C4018 MmaxVal

100.0

Limit value for max. torque
(M

max

)

0.01

{0.01 %}

100.00

l

100 % = maximum torque
from C0057

l

The value in C4018 is
overwritten by the following
functions:

– Torque limitation after

positioning

^ 208

– Homing modes 14 and 15

(C3010)

^ 186

[C4020] Brake Logic

0

Activation of brake logic

^ 130

0

Brake Off

1

Brake On

C4021 Brk: T_activ

500

Closing time of the motor
holding brake (engagement
time)

^ 130

0

{1 ms}

5000

C4022 Brk: T_releas

500

Release time of the motor
holding brake (disengagement
time)

^ 130

0

{1 ms}

5000