Commissioning

Setting the positioning profile
Selecting a positioning profile mode

6

l

192

EDBCSXP064 EN 8.0

You can select the following positioning profile modes via C3095/x:

Positioning profile mode

Setting

C3095/x

Detailed

description

Absolute positioning

0

^ 193

Relative positioning in continuous measuring system

1

^ 193

Continuous constant travel

2

^ 195

Relative positioning with absolute reference

3

^ 194

Absolute touch probe positioning

Rising edge at X6/DI3

10

^ 194

Falling edge at X6/DI3

20

Relative touch probe positioning in the
continuous measuring system

Rising edge at X6/DI3

11

^ 195

Falling edge at X6/DI3

21

Relative touch probe positioning with absolute
reference

Rising edge at X6/DI3

13

^ 195

Falling edge at X6/DI3

23

Electrical shaft ("EShaft")

Setpoint via encoder input X8

30

^ 196

Setpoint via MotionBus (CAN)
X4

31

Setpoint via EtherCAT
(EMF2192IB at AIF
interface X1)

32

Homing

100

^ 197

Set reference

101

^ 197

Reset home position

102

^ 197

Direct positioning

Absolute positioning (direct)

110

^ 198

Relative positioning in
continuous measuring system
(direct)

111

^ 198

Continuous constant travel
(direct)

112

^ 199

Relative positioning with
absolute reference (direct)

113

^ 199

Positioning sequence for controller optimisation

251

^ 200