Troubleshooting and fault elimination

Fault messages
Reset fault messages (TRIP−RESET)

11

l

352

EDBCSXP064 EN 8.0

11.3.2

Reset fault messages (TRIP−RESET)

Response

Measures to reset the fault message

TRIP/FAIL−QSP

Note!
As long as a TRIP/FAIL−QSP source is active, the TRIP/FAIL−QSP cannot be reset.

The TRIP/FAIL−QSP can be reset by:

l

Press keypad XT EMZ9371 BC

ð S. Then, press U to re−enable the axis module.

l

Set code C4166 = 1.

l

Control word "Ctrl1": Control bit Ctrl1.TripReset (

^ 158)

(Dependent on the control interface selected in C4010.)

l

Control word AIF (from V3.0)

After the TRIP/FAIL−QSP has been reset, the drive remains at standstill.

Message

Danger!
After the fault has been removed, the fault message is removed automatically and the drive
restarts automatically.

Warning

After eliminating the fault, the fault message is reset automatically.