Diagnostics with Global Drive Oscilloscope (GDO)
Diagnostics with GDO

10

l

328

EDBCSXP064 EN 8.0

10.2.2

Diagnostics with GDO

1. Connect controller via terminal X4 (CAN) or X14 (CAN−AUX) with PC system bus

adapter to PC/laptop.

2. Supply controller with a control voltage of 24 V (

^ 64).

3. Start the GDO on the PC/Laptop.

4. Press the button Connect device.

– The dialog "Select device" opens (Fig. 10−5).
– The devices connected to the bus are listed under "Online".

ECSXA481

Fig. 10−5

GDO view: dialog "Select device"

5. Select the corresponding device under Online and click on the OK button.

– The dialog "Select DDS project symbol file" opens:

ECSXA482

Fig. 10−6

GDO view: dialog "Select DDS project symbol file"

6. Select symbol file ECSPOS_Axxx.SDB (xxx = version number) and press button OK .