Commissioning – Lenze ECSCPxxx User Manual

Page 132

Advertising
background image

Commissioning

Setting of the feedback system for position and speed control

6

l

132

EDBCSXP064 EN 8.0

6.9

Setting of the feedback system for position and speed control

The following feedback systems can be selected for position and speed control:

ƒ

Resolver (

133)

ƒ

TTL incremental encoder/SinCos encoder without serial communication (

136)

– as position and speed encoder (

136)

– as position encoder and resolver as speed encoder (

140)

ƒ

Absolute value encoder (Hiperface®, single−turn/multi−turn)
– as position and speed encoder (

145)

– as position encoder and resolver as speed encoder (

150)

The GDC includes the parameters or codes to be set in the parameter menu under
Short setup

W Feedback system:

ECSXA441

Fig. 6−24

GDC view: Commissioning of the feedback system

More parameters or codes for setting the feedback system can be found in the parameter
menu under Motor/feedback system

W Feedback system.

)

Note!

If the Lenze setting has been loaded via C0002, the feedback system must be
reset.