Commissioning

Setting the positioning profile

Homing

6

l

197

EDBCSXP064 EN 8.0

6.17.6

Homing

6.17.6.1

Homing

C3095/x = 100

ƒ

Homing is carried out according to the selected homing mode (

179).

ƒ

For homing parameters see

^ 177.

ƒ

The status bit Stat1.HomePosAvailable is set to "1" after a successful execution
(monitoring of the software limit positions is activated).

6.17.6.2

Setting the reference

C3095/x = 101

ƒ

The current position is stored as the home position and used as the measuring
system reference.

ƒ

The drive does not move.

ƒ

The status bit Stat1.HomePosAvailable is set to "1" (monitoring of the software limit
position is activated).

ƒ

In case of feedback system of type AM:
– When the reference is set, the controller must be inhibited (Ctrl1.Cinh = 1).
– The home position is maintained after switching off and on again the control

voltage of the drive.

Preconditions

ƒ

Status bit Stat1.HomePosAvailable = 0; if required, execute the "Reset reference"
function first (see below).

6.17.6.3

Reset reference (Reset HomePosAvailable)

C3095/x = 102

ƒ

The reference of the measuring system to the home position is cancelled.

ƒ

The status bit Stat1.HomePosAvailable is set to "0" (monitoring of the software limit
position is deactivated).