Description

Display

format

Display

Code

Signal

type

Data type

Variable

designation

g_DCTRL_bRdy_b

y

TRUE = ready for operation

g_DCTRL_bCwCCw_b

TRUE = counter−clockwise rotation,
FALSE = clockwise rotation

g_DCTRL_bNActEq0_b

TRUE = motor speed < C0019

g_DCTRL_bCInh_b

TRUE = controller inhibit active

g_DCTRL_bExternalFault_b

TRUE = external fault

g_MCTRL_bQspOut_b

C0907/3

bin

TRUE = drive carries out quick stop
(QSP)

g_MCTRL_nHiMLim_a

integer

analog

C0906/4

dec [%]

Upper torque limitation

l

in % of C0057

g_MCTRL_nLoMLim_a

C0906/3

Lower torque limitation

l

in % of C0057

g_MCTRL_bNMSwt_b

Bool

binary

C0907/2

bin

TRUE = torque control
FALSE = speed control

g_MCTRL_bnNAdapt_a

integer

analog

Adaptive Vp of the speed controller

g_MCTRL_bILoad_b

Bool

binary

C0907/4

bin

TRUE = integral action component
of the speed controller is accepted
by MCTRL_nISet_a.

g_MCTRL_nISet_a

integer

analog

C0906/8

dec [%]

Integral action component of the
speed controller

g_MCTRL_nPAdapt_a

C0906/9

Influence of C0254 on Vp (in %)

l

The sum (without sign) is
edited.

g_MCTRL_nPosLim_a

C0906/5

dec [%]

Influence of the angle controller

l

in % of n

max

(C0011)

g_MCTRL_bPosOn_b

Bool

binary

C0907/1

TRUE = activate angle controller

g_MCTRL_nNStartMLim_a

integer

nalog

C0906/6

dec [%]

Lower speed limit at speed
limitation

g_MCTRL_nMAdd_a

C0906/2

Additional torque setpoint or
torque setpoint

g_MCTRL_nFldWeak_a

C0906/7

Motor control

g_MCTRL_bQspIn_b

Bool

binary

binary

C0042

bin

TRUE = drive carries out quick stop
(QSP)

g_MCTRL_bMMax_b

TRUE = speed controller operates
within the limitation.

g_MCTRL_bIMax_b

Bool

binary

binary

TRUE = drive operates at current
limit C0022.

g_MCTRL_bUndervoltage_b

Monitoring: undervoltage

g_MCTRL_bOvervoltage_b

Monitoring: overvoltage

g_MCTRL_bShortCircuit_b

Monitoring: short circuit

g_MCTRL_bEarthFault_b

Monitoring: earth fault

g_MCTRL_bIxtOverload_b

Monitoring: I x t overload

g_MCTRL_bNmaxFault_b

Monitoring: max. system speed
exceeded.

g_MCTRL_nNmaxC11

integer

Display of max. speed (C0011)

g_MCTRL_bActTPReceived_b

Bool

binary

Touch Probe (TP) received.

g_MCTRL_bActIncLastScan_b

double

integer

position

Dinc between Touch Probe (TP) and
Start of Task

g_MCTRL_bResolverFault_b

Monitoring: Resolver fault

g_MCTRL_bEncoderFault_b

Monitoring: Encoder fault

g_MCTRL_bSensorFault_b

Monitoring: Absolute value
encoder fault

Advertising