Commissioning – Lenze ECSCPxxx User Manual

Page 245

Advertising
background image

Commissioning

Operation with motors from other manufacturers

Entering motor data manually

6

l

245

EDBCSXP064 EN 8.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0018 fchop

2

Switching frequency

1

4 kHz sin

4 kHz permanent PWM
frequency

2

8/4 kHz sin

8 kHz PWM frequency with
automatic derating to 4 kHz at
high load

C0022 Imax current

à

I

max

limit

0

{0.01 A}

à

Device−dependent list

Max. current can be gathered
from the technical data.

[C0081] Mot power

3.20

Rated motor power according to
nameplate

0.01

{0.01 kW}

500.00

[C0084] Mot Rs

1.10

Stator resistance of the motor
The upper limit is
device−dependent.

0.00

{0.01

W}

95.44 ECSxS/P/M/A004

47.72 ECSxS/P/M/A008

23.86 ECSxS/P/M/A016

11.93 ECSxS/P/M/A032

7.95 ECSxS/P/M/A048

5.96 ECSxS/P/M/A064

[C0085] Mot Ls

5.30

Leakage inductance of the motor

0.00

{0.01 mH}

200.00

[C0087] Mot speed

3700

Rated motor speed

300

{1 rpm}

16000

[C0088] Mot current

7.0

Rated motor current

0.5

{0.1 A}

500.0

[C0089] Mot

frequency

185

Rated motor frequency

10

{1 Hz}

1000

[C0090] Mot voltage

325

Rated motor voltage

50

{1 V}

500

[C0091] Mot cos phi

1.0

cos

j of the asynchronous motor

0.50

{0.01}

1.00

C0128 Tau motor

5.0

Thermal time constant of the
motor

^ 309

0.5

{0.1 min}

25.0 For calculating the I

2

x t

disconnection

C2108 PLC run/stop

(Posi & Shaft)

2

{1}

PLC programcontrol

0

No function

1

Run

2

Stop

3

Reset