Function monitoring of thermal sensors (h10, h11), Monitoring functions – Lenze ECSCPxxx User Manual

Page 305

Advertising
background image

Monitoring functions

Configuring monitoring functions

Function monitoring of thermal sensors (H10, H11)

9

l

305

EDBCSXP064 EN 8.0

9.3.8

Function monitoring of thermal sensors (H10, H11)

The function of the thermal sensors of the heatsink and the interior of the device is
monitored. If the thermal sensors report values outside the measuring range, fault H10
(heatsink) or H11 (interior) is reported. The response to these faults can be defined under
C0588.

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0588 MONIT

H10/H11

0

Fault response − monitoring
Thermal sensors in the
controller.
H10: Sensor inside the device
H11: Heatsink sensor

^ 305

0

TRIP

2

Warning

3

Off