Appendix – Lenze ECSCPxxx User Manual

Page 376

Advertising
background image

Appendix

Code table

12

l

376

EDBCSXP064 EN 8.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0470

Freely configurable code for
digital signals
Hexadecimal value is bit−coded.

1 FCODE 8bit

0

00

{hex}

FF C0470/1 = C0471, bit 0 ... 7

2 FCODE 8bit

0

C0470/2 = C0471, bit 8 ... 15

3 FCODE 8bit

0

C0470/3 = C0471, bit 16 ... 23

4 FCODE 8bit

0

C0470/4 = C0471, bit 24 ... 31

C0471 FCODE 32bit

0

Hexadecimal 32−bit
interpretation of C0470

0

{1}

4294967295

C0472 FCODE analog

Freely configurable code for
relative analog signals

1

0.0

−199.99

{0.01 %}

199.99 FCODE_bC472_1_a

2

0.0

FCODE_bC472_2_a

3

100.0

FCODE_bC472_3_a

4

0.0

FCODE_bC472_4_a

...

...

...

20

0.0

FCODE_bC472_20_a

C0473

Freely configurable code for
absolute analog signals

1 FCODE abs

1

−32767

{1}

32767

2 FCODE abs

1

3 FCODE abs

0

... ...

...

10 FCODE abs

0

C0474

Freely configurable code for
phase signals

1 FCODE PH

0

−2147483647

{1}

2147483647

... ...

...

5 FCODE PH

0

C0475

Freely configurable code for
phase difference signals

1 FCODE DF

0

−16000

{1 rpm}

16000

2 FCODE DF

0

[C0490] Feedback pos

0

Selection of feedback system for
positioning control

^ 132

0

Resolver at X7

Standard setting

1

TTL encoder at X8

l

Sets C0419 = 0 ("Common") if
a different encoder type as
under C0419 is set here.

2

SinCos encoder at X8

3

Absolute value encoder (single−turn) at
X8

4

Absolute value encoder (multi−turn) at
X8

Advertising
This manual is related to the following products: