Commissioning

Commissioning steps (overview)
Setting absolute positioning/relative continuous positioning

6

l

124

EDBCSXP064 EN 8.0

Operation with a linear positioning axis

Operation with a continuous positioning axis

5.

Inhibit controller.

l

Press the <F9> key in GDC.

l

X6/SI1 orX6/SI2 must be open (LOW).

l

C4040/bit 9 = 1 (Ctrl1.Rsp)

6.

Set the operating mode required for the application via C4010 in the GDC parameter menu under Short
setup

W Operating mode. (^ 226)

The settings for travel with absolute positioning or relative positioning in the continuous
measuring system are completed.

Proceed as follows:

ƒ

Save parameters in the controller with C0003 = 1.

ƒ

Save parameter set with GDC in the parameter set file.

ƒ

Enable controller (

^ 252).

ƒ

Optimise drive behaviour (

^ 252).