Appendix
Code table
l
369
EDBCSXP064 EN 8.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C0352 CAN mst
0
Boot−up master/slave
configuration for CAN bus
interface X4
^ 273
0
Slave
1
Master boot−up
Device is active as CAN boot−up
master.
2
Master node guarding
3
Slave heartbeat producer
4
Slave node guarding
C0353
Source for node address of
CAN_IN/CAN_OUT (CAN bus
interface X4)
^ 271
1 CAN addr sel
0
CAN node address (C0350)
Address CAN1_IN/OUT
2 CAN addr sel
0
CAN node address (C0350)
Address CAN2_IN/OUT
3 CAN addr sel
0
CAN node address (C0350)
Address CAN3_IN/OUT
0
C0350 (auto)
Automatically determined by
C0350.
1
C0354 (man.)
Determined by C0354.
C0354
Alternative node address for
CAN_IN/CAN_OUT (CAN bus
interface X4)
^ 271
1 CAN addr.
129
1
{1}
512 Address 2 CAN1_IN
2 CAN addr.
1
Address 2 CAN1_OUT
3 CAN addr.
257
Address 2 CAN2_IN
4 CAN addr.
258
Address 2 CAN2_OUT
5 CAN addr.
385
Address 2 CAN3_IN
6 CAN addr.
386
Address 2 CAN3_OUT
C0355
Identifier for CAN_IN/CAN_OUT
(CAN bus interface X4)
Read only
^ 429
1 CAN Id
1
{1}
2047 Identifier CAN1_IN
2 CAN Id
Identifier CAN1_OUT
3 CAN Id
Identifier CAN2_IN
4 CAN Id
Identifier CAN2_OUT
5 CAN Id
Identifier CAN3_IN
6 CAN Id
Identifier CAN3_OUT
C0356
CAN time settings for CAN bus
interface X4
^ 274
1 CAN times
3000
0
{1 ms}
65000 CAN boot−up time:
Delay time after mains
connection for initialisation
through the master.
2 CAN times
0
CAN2...3_OUT cycle times:
Factor for the task time to send
process data telegram.
0 = event−controlled
transmission
3 CAN times
0
4 CAN times
20
Delay time for initial
transmission of the process data
objects 2 and 3 after the CAN bus
changed to "Operational"