Appendix – Lenze ECSCPxxx User Manual

Page 369

Advertising
background image

Appendix

Code table

12

l

369

EDBCSXP064 EN 8.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0352 CAN mst

0

Boot−up master/slave
configuration for CAN bus
interface X4

^ 273

0

Slave

1

Master boot−up

Device is active as CAN boot−up
master.

2

Master node guarding

3

Slave heartbeat producer

4

Slave node guarding

C0353

Source for node address of
CAN_IN/CAN_OUT (CAN bus
interface X4)

^ 271

1 CAN addr sel

0

CAN node address (C0350)

Address CAN1_IN/OUT

2 CAN addr sel

0

CAN node address (C0350)

Address CAN2_IN/OUT

3 CAN addr sel

0

CAN node address (C0350)

Address CAN3_IN/OUT

0

C0350 (auto)

Automatically determined by
C0350.

1

C0354 (man.)

Determined by C0354.

C0354

Alternative node address for
CAN_IN/CAN_OUT (CAN bus
interface X4)

^ 271

1 CAN addr.

129

1

{1}

512 Address 2 CAN1_IN

2 CAN addr.

1

Address 2 CAN1_OUT

3 CAN addr.

257

Address 2 CAN2_IN

4 CAN addr.

258

Address 2 CAN2_OUT

5 CAN addr.

385

Address 2 CAN3_IN

6 CAN addr.

386

Address 2 CAN3_OUT

C0355

Identifier for CAN_IN/CAN_OUT
(CAN bus interface X4)
Read only

^ 429

1 CAN Id

1

{1}

2047 Identifier CAN1_IN

2 CAN Id

Identifier CAN1_OUT

3 CAN Id

Identifier CAN2_IN

4 CAN Id

Identifier CAN2_OUT

5 CAN Id

Identifier CAN3_IN

6 CAN Id

Identifier CAN3_OUT

C0356

CAN time settings for CAN bus
interface X4

^ 274

1 CAN times

3000

0

{1 ms}

65000 CAN boot−up time:

Delay time after mains
connection for initialisation
through the master.

2 CAN times

0

CAN2...3_OUT cycle times:
Factor for the task time to send
process data telegram.
0 = event−controlled
transmission

3 CAN times

0

4 CAN times

20

Delay time for initial
transmission of the process data
objects 2 and 3 after the CAN bus
changed to "Operational"

Advertising