Commissioning

Controller enable (CINH = 0)

6

l

242

EDBCSXP064 EN 8.0

The following table describes the status displays for the controller inhibit (Cinh) /
controller enable:

Status display

Controller inhibited

Enable controller

Comment

Green LED

Blinking

Constantly ON

C0183 drive
diagnostics

Display of the signal
source for controller
inhibit (Cinh)

Display "OK"

See GDC menu "Diagnostics / Device
current status" or GDC monitor window
down right

C0150 DCTRL status
word Bit 7 (CINH
active)

C0150.Bit07 = 1

C0150.Bit07 = 0

See GDC menu "Diagnostics / display
MCTRL"

Keypad text display
"IMP"

"IMP"

"IMP" not displayed

)