Commissioning – Lenze ECSCPxxx User Manual

Page 144

Advertising
background image

Commissioning

Setting of the feedback system for position and speed control
TTL/SinCos encoder as position encoder and resolver as speed encoder

6

l

144

EDBCSXP064 EN 8.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

[C0491] X8 in/out

0

Function of X8

^ 132

0

X8 is input

Use as encoder feedback or
master frequency input for
positioning profile mode
C3095/x = 30 (electrical shaft
with setpoint via X8)

1

X8 is output

Use as encoder feedback or
master frequency output during
master operation (electrical shaft
as setpoint via X8)

C3001 EncDirInv

0

Position encoder mounting
position

0

Normal (direction of rotation CW)

Direction of rotation with regard
to the motor’s direction of
rotation

1

Inverse (direction of rotation CCW)

Advertising
This manual is related to the following products: