Commissioning

Setting the positioning profile

Selecting a positioning profile mode

6

l

191

EDBCSXP064 EN 8.0

6.17

Setting the positioning profile

Up to 15 positioning profiles can be set in the ECSxP axis module to execute the different
positioning tasks required for a machine.

For setting a positioning profile, carry out the following steps:

ƒ

Select the positioning profile mode via C3095. (

¶ 191)

ƒ

Set positioning profile parameters. (

201)

ƒ

Configure the additional functions of the positioning profile. (

204)

The Global Drive Control (GDC) contains the corresponding codes in the parameter menu
under Profile 01..15.

ECSXA445

Fig. 6−45

GDC view: Setting of positioning profiles

6.17.1

Selecting a positioning profile mode

)

Note!

ƒ

The target position in C3100 must be between the positive and negative
value from C4265 (max. target position selection).
– Example: C4265 = 10000

ð C3100 = −10000 ... +10000

ƒ

The maximum traversing range amounts to 2147483649 increments for all
positioning profile modes (2

31

− 1).

ƒ

The position display C3051 is limited to ± 214000,0000 units.