Commissioning

Holding brake configuration

6

l

131

EDBCSXP064 EN 8.0

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

[C0420] Encoder const.

512

Number of increments of the
encoder

^ 136

^ 145

1

{1 inc/rev}

8192 Sets C0419 = 0 ("common") if the

value is altered.

C4021 Brk: T_activ

500

Closing time of the motor
holding brake (engagement
time)

^ 130

0

{1 ms}

5000

C4022 Brk: T_releas

500

Release time of the motor
holding brake (disengagement
time)

^ 130

0

{1 ms}

5000

C4023 Brk: N_Thresh

0.1 %

Speed threshold for brake
activation

^ 130

0.00

{0.01 %}

10.00

C0118

Polarity of the digital outputs
(DIGOUT)

^ 172

1 DIGOUT pol

0

HIGH level active

X6/DO1

2 DIGOUT pol

0

HIGH level active

X25/BD1, X25/BD2
(brake connection)

0

HIGH level active

1

LOW level active

C0602 MONIT REL1

3

Fault response − open circuit
monitoring of relay output X25

0

TRIP

2

Message

3

Off

4

FAIL−QSP

Advertising