Commissioning – Lenze ECSCPxxx User Manual

Page 246

Advertising
background image

Commissioning

Operation with motors from other manufacturers
Checking the direction of rotation of the motor feedback system

6

l

246

EDBCSXP064 EN 8.0

6.29.2

Checking the direction of rotation of the motor feedback system

In GDC, you can find the parameters and codes to be set in the parameter menu under
Motor/Feedback systems

W Feedback system.

ECSXA449

Fig. 6−63

GDC view: Feedback system

C0060 indicates the rotor position within one revolution as a numerical value between 0

and 2047. The indicated rotor position is derived from the selected position encoder

(C0490) with reduced resolution.

Evaluation:

If the motor encoder (resolver) is set as position encoder (C0490) and the rotor rotates in
CW direction (view on the front of the motor shaft), the numerical value must rise. If the
values are falling, reverse the Sin+ and Sin− connections.

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C0060 Rotor pos

Current rotor position; value is
derived from position encoder.
Therefore, it is only valid as rotor
position if the position encoder
settings under C0490 are
identical with the settings of the
speed encoder on the motor
shaft under C0495.
Read only

^ 246

0

{1 inc}

2047 Display with reduced resolution:

1 revolution = 2048 increments

Advertising