Appendix

Code table

12

l

368

EDBCSXP064 EN 8.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0202

Service code
Only display

1

Product code 1

...

...

4

Product code 4

C0203 Komm.−No.

x / xxxx / xxxxx

Commission number
Only display

C0204 Serial−No.

Serial number
Read only

C0205 PLC Target ID

Identification key
Only display

C0206 Product. date

Production date
Only display

C0207 DL info 1

Download info 1
Only display

C0208 DL info 2

Download info 2
Only display

C0209 DL info 3

Download info 3
Only display

C0250 FCODE 1 Bit

0

Freely selectable digital signal
(1 bit)

0

1

C0254 Vp angle CTRL

0.4000

Phase controller gain (V

p

)

0.0000

{ 0.0001}

3.9999

C0300 Service Codes

Only the Lenze service is allowed
to make changes!

...

C0302

C0349

Status of the DIP switch for CAN
bus interface X4
Read only

1 CAN DIP−SW

0

{1}

63 Node address set on the DIP

switch

2 CAN DIP−SW

0

4 For setting the DIP switches > 4,

the display is set to 0.

C0350 CAN address

32

Node address for CAN bus
interface X4

l

This code is not active if one
of the switches 2 ... 7 of the
DIP switch is set to "ON".
(

^ 266)

l

After the setting process, a
reset node is required.

l

A definite node address must
be assigned to each CAN
node.

^ 266

^ 429

1

{1}

63

C0351 CAN baud rate

0

Baud rate for CAN bus interface
X4

l

The baud rate must be set
identically for all CAN nodes.

l

This code is not active if one
of the switches 2 ... 7 of the
DIP switch is set to "ON".

l

After the setting process, a
reset node is required.

^ 266

0

500 kbps

1

250 kbits/sec

2

125 kbit/s

3

50 kbps

4

1000 kbit/s