background image

Diagnostics

Diagnostics with Global Drive Oscilloscope (GDO)
Diagnostics with GDO

10

l

332

EDBCSXP064 EN 8.0

Description

Display

format

Display

Code

Signal

type

Data type

Variable

designation

g_MCTRL_bMotorTempGrea
terSetValue_b

Bool

binary

Monitoring: Motor
temperature > 150 °C

g_MCTRL_bMotorTempGrea
terC0121_b

Monitoring: Motor
temperature > C0121

g_MCTRL_bPtcOverTemp_b

Monitoring: Motor
overtemperature (PTC)

g_MCTRL_bKuehlGreaterSet
Value_b

Monitoring: Heatsink
temperature > 90 °C

g_MCTRL_bKuehlGreaterC01
22_b

Monitoring: Heatsink
temperature > C0122

g_bDigin_bIn1_b

Bool

binary

C0443

bin

Digital inputs

g_bDigin_bIn2_b

g_bDigin_bIn3_b

g_bDigin_bIn4_b

g_bDigin_Save_Standstill_b

Safe torque off (formerly "safe
standstill")

g_bDigout_bOut_b

Bool

binary

C0444/1

bin

Digital output

g_bDigout_bRelais_b

C0444/2

Feedback "safe torque off"
(formerly "safe standstill")

g_nAin_nIn_a

integer

analog

C0400

dec [%]

Analog input

g_nAin_bError_b

Bool

binary

TRUE if I < 2 mA

Advertising