20 setting the target position window (intarget), Commissioning – Lenze ECSCPxxx User Manual

Page 229

Advertising
background image

Commissioning

Setting the target position window (InTarget)

6

l

229

EDBCSXP064 EN 8.0

6.20

Setting the target position window (InTarget)

The C3034 target position window serves to set a window for the "Target position
reached" message. The entered target window is positioned around the target position
which is in the middle of it. The settings can be made in the GDC parameter menu under
Positioning

W Machine parameters.

ƒ

The status message "Target reached" is set (status bit Stat1.InTarget = 1) as soon as
the actual position has reached the target window which is positioned around the
positioning target.

ƒ

Only for constant travel modes (C3095 = 2 or 112):
The target position is defined as the position where standstill has been reached for the
first time when stopping. Then the target position window is set around this position
and the Stat1.InTarget status bit is set to "1" as long as the current position is within the
window.

Target position

C3034 = 81

80 [unit]

40 [unit]

40 [unit]

Target window

ECSXA414

Fig. 6−56

Symmetrical structure of the target position window

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

C3034 Target

Window

360.0

Total width of the target position
window
Layout: Half of the window
width before and after the target
position

^ 229

−0.0000

{0.0001

units}

65536.0000

Advertising