Appendix – Lenze ECSCPxxx User Manual

Page 385

Advertising
background image

Appendix

Code table

12

l

385

EDBCSXP064 EN 8.0

IMPORTANT

Possible settings

Code

Selection

Lenze/
{Appl.}

Designation

No.

C0906

Analog input signals to MCTRL
Read only

1 MCTRL analog

−199.99

{0.01 %}

199.99 Speed controller input

2 MCTRL analog

Torque setpoint

3 MCTRL analog

Lower torque limit

4 MCTRL analog

Upper torque limit

5 MCTRL analog

Limit of the position controller

6 MCTRL analog

Speed for activating the torque
limitation

7 MCTRL analog

Field weakening

8 MCTRL analog

Integrator of the speed controller

9 MCTRL analog

P adaptation of the position
controller

C0907

Digital input signals to MCTRL
Only display

1 MCTRL digital

0

1 Activating position controller

2 MCTRL digital

Speed control or torque control

3 MCTRL digital

Set quick stop (QSP)

4 MCTRL digital

Loading integral−action
component of the speed
controller

C0908 MCTRL PosSet

Set phase signal
1 revolution = 65536 increments
Only display

−2147483648

{1 inc}

2147483647

C0909 speed limit

1

Limitation of direction of
rotation for speed setpoint

1

−175 ... +175 %

2

0 ... +175 %

3

−175 ... 0 %

C0910 MCTRL TP2

delay

0

MCTRL dead time compensation
TP2 (X6/DI2)

−32767

{1 inc}

32767 1 inc

º approx. 60 ms

C0911 MCTRL TP2

sel.

0

MCTRL touch probe signal source

0

Zero pulse of position encoder (C0490) X7/X8

1

Touch probe input TP2

X6/DI2

C0912 MCTRL TP2

Edge

0

MCTRL touch probe TP2 edge
(for touch probe via digital input
X6/DI2 (C0911 = 1))

0

Rising edge TP2

1

Falling edge TP2

2

Rising and falling edge TP2

3

Switched off

C1120 Sync mode

0

Sync signal source

^ 278

0

Off

Off

1

CAN sync

Sync connection via interface X4
(CAN)

^ 282

2

Terminal sync

Sync connection via terminal
X6/DI1

^ 283