Commissioning – Lenze ECSCPxxx User Manual
Page 167
![background image](/manuals/566247/167/background.png)
Commissioning
Entry of machine parameters
l
167
EDBCSXP064 EN 8.0
IMPORTANT
Possible settings
Code
Selection
Lenze/
{Appl.}
Designation
No.
C3035 DwellTime
50
Dwell time after end of profile
^ 232
0
{1 ms}
65535 Time required from positioning
profile end (setpoint generator
has reached target position) to
the setting of status bit
Stat1.DwellTime = 1
C3036 BounceTime
0
Debounce time for touch probe
input
0
{0.001 ms}
65535
C3040 SW−LimPos
3600.0
Positive software limit position
^ 237
0.0000
{0.0001
units}
214000.0000
C3041 SW−LimNeg
−3600.0
Negative software limit position
^ 237
−214000.0000
{0.0001
units}
0.0000
C4018 MmaxVal
100.0
Limit value for max. torque
(M
max
)
0.01
{0.01 %}
100.00
l
100 % = maximum torque
from C0057
l
The value in C4018 is
overwritten by the following
functions:
– Torque limitation after
positioning
^ 208
– Homing modes 14 and 15
(C3010)
^ 186
C4060 ES_NOffs
Only for "electrical shaft"
function: default value (in
increments) for
speed−proportional angular
trimming relating to
15000 rev./min.
Note: Only change value when
the controller is at standstill!
^ 235
−655360
{1 inc}
655360