Commissioning – Lenze ECSCPxxx User Manual

Page 169

Advertising
background image

Commissioning

Configuring the digital inputs and outputs

6

l

169

EDBCSXP064 EN 8.0

Code

Possible settings

IMPORTANT

No.

Designation

Lenze/
{Appl.}

Selection

[C4011] DigIn_map

0

Assignment of the digital inputs
X6/DI1 ... DI4
Acceptance only if the controller
is inhibited (status word
Stat1.Imp = 1).

^ 168

DI1

DI2

DI3

DI4

Ix: Input x is not assigned with a
function.
JogCW: Manual jog CW
JogCCW: Manual jog CCW
Ln: Limit switch in negative
direction
Lp: Limit switch in positive
direction
PNo1: Selection of positioning
profile bit 2

0

PNo2: Selection of positioning
profile bit 2

1

PNo4: Selection of positioning
profile bit 2

2

PNo8: Selection of positioning
profile bit 2

3

Penb: Positioning profile
activated (enable)
Qsp: Quick stop (QSP)
R: TRIP−RESET
Ref: Reference switch
TP: Touch probe input

0

Ln Ref TP Lp

1

PNo1 PNo2 PNo4 PNo8

2

PNo1 PNo2 PNo4 PEnb

3

PNo1 PNo2 R

PEnb

4

Qsp JogCW

Tp JogCCW

5

I1

I2 TP I4

6

Ln

Qsp

Penb

Lp

7

PNo1

PNo2

TP

Penb

8

PNo1

PNo2

Ref

Penb

9

Ln

PNo1

PNo2

Lp

10

Ln

JogCW

JogCCW Lp

11

Ln

Ref

Penb

Lp

12

Ln

Ref

Qsp

Lp

13

Ln

Qsp

TP

Lp

[C4012] DigOut_map

0

Assignment of digital output
X6/DO1
Acceptance only if the controller
is inhibited (status word
Stat1.Imp = 1).

^ 168

0

RDY

Rdy: Drive is ready for operation.

Advertising
This manual is related to the following products: