3 configuring the receiver for real-time reference, Operations – Leica Geosystems GPS System 500 - Technical Reference Manual User Manual

Page 116

Advertising
background image

116

5. Configuring the Receiver

Technical Reference Manual-4.0.0en

5.3 Configuring the Receiver for Real-Time Reference Operations

This section covers configuration of
the receiver for Real-Time Reference
Operations. Note that Real Time
Reference Operations are only
possible with an SR530 (Real-Time to
centimeter level) or an SR510 or 520
that has the RTCM 2.x option
activated (DGPS to 0.5 - 5m level).

Highlight the Configuration Set you
wish to edit and press CONT (F1).
Note that you cannot edit default
Configuration Sets. You have to
create a new one and then edit it.

Operation Mode
Select the Operation Mode that you
require. The Operation Mode defines
which Configuration screens will be
available to you.

You may choose between Standard
and Advanced. Standard is
recommended for most users.
Advanced enables definition of
parameters required for scientific
research and other specialized
applications.

When you have made your selection
press CONT (F1) to go through the
fixed order of parameter panels.

Or press LIST (F6) to get a listing of
the available parameter panels which
can then be accessed individually
with CONT (F1). Changes are
automatically stored at the end of the
list. Changes in individual parameter
panels can be stored with STORE
(F3)
without the need to go to the end
of the list.

The Standard Operation mode is
described from here on. The extra
configurable features available when
Advanced is selected are described in
the next section.