Leica Geosystems GPS System 500 - Technical Reference Manual User Manual

Page 189

Advertising
background image

189

7. Measuring with System 500

Technical Reference Manual-4.0.0en

You may either:
Press ESC to return to the survey
screen, check and correct the
antenna height or point Id, then
rerecord the interval. Your previous,
incorrect interval will be deleted.
or
Highlight an interval that is incorrect
and press DEL (F4) to delete the
interval. Then press CONT (F1) to
return to the survey screen.
or
With INFO (F5) toggle between
different information for each interval.
or
Highlight an interval and press USE
(F2) to include or exclude a
measurement from calculating the
absolute coordinate difference. An
absolute coordinate difference can
only be calculated between two
measurements. After having set the
use flag for two measurements to Y,
press DIFF (F3) to display the
absolute coordinate differences.

Should a point fall within the threshold
settings and the system is set to
absolute coordinate differences, you
may press ABS (F2).

or
Highlight the interval that is incorrect
and press USE (F2) to deselect the
interval. Then press CONT (F1) to
return to the survey screen.
or
Highlight the interval that is incorrect
and press DEL (F4) to delete the
interval.Then press CONT (F1) to
return to the survey screen.
or
With INFO (F5) toggle between
different information for each interval.

The intervals are displayed with time
when they were recorded, and the
coordinate quality and class.

Should a point fall outside of these
threshold settings, this panel will be
accessed automatically. Common
reasons for this happening are an
incorrect antenna height or a wrong
point Id. The use flag for this point is
then set to N for no.