386

Appendix K

Technical Reference Manual-4.0.0en

If a user defined point template mask
is used on GS50 / GS50+, for
example “Point ###” with an
increment value 1, the Point Id is
shown in the first line of the attribution
panel.

Assume the last measured point was
“Point 202”, then the next proposed
id is “Point 203”. The Point Id cannot
be overwritten manually.

Nevertheless the enumeration value
203 is changeable. During GIS point
data collection, Shift ENUM (F5)
leads to the following panel.

Entering a different enumeration and
CONT (F1) changes the Id enumera-
tion immediately.

Configuration: Occupation settings

The configuration option Auto
STORE
is not available for GIS Data
collection. This is because the GS50 /
GS50+ always stores automatically.

This change applies to chapters 5.1,
5.2 and 5.4.

In Advanced mode, the End Survey
option is also not available. This is
because the GIS Data Collection can
only be exited manually. Additionally,
the Auto OCUPY option is not
available because occupation always
starts manually.

To configure the number of averaged
positions for nodes, press NODES
(F4)
in the Configure\ Occupation
Settings panel.

This change applies to chapters
5.1.1, 5.2.1 and 5.4.1.

Configuration: Logging

The configuration of logging for auto
logged positions
is not available for
GIS Data Collection. This is because
the autologged positions are not
connected to any topology.

The GIS Data Collection program
employs a different method to collect
points automatically which is more
suited to GIS data collection.

For post-processing of lines and
areas measured in stream mode
(START-STOP), it is mandatory to set
Log Static and Log Moving to YES.

This change applies to chapters 5.1,
5.2 and 5.4.