Leica Geosystems GPS System 500 - Technical Reference Manual User Manual

Page 285

Advertising
background image

285

11. Applications

Technical Reference Manual-4.0.0en

Pressing INFO (F5) again reveals the
CQ (coordinate quality) and the
coordinate class. The coordinate
class in ascending order may be:

MEAS - Point measured once
AVRG - Point measured more than
once and coordinates averaged.
Regardless of whether Avg or Abs is
selected in the Threshold settings,
points with more than one associated
measured point will still be shown as
average here.
CTRL - Point user entered or held
fixed with no accuracy matrix.

Use NEW (F2) to enter a new point.
Enter the new point Id and the
coordinates. Use the COORD (F2)
key to switch between Coordinate
Systems.

If the panel shows local grid
coordinates you may use the ELL H/
ORTHO (F5) key to switch between
entering orthometric or local
ellipsoidal heights.
When you have entered the point
details press STORE (F1) to store the
point and return to the previous
screen.

Use EDIT (F3) to view the
coordinates and point annotations of
a selected point or to edit the point ID.
Unless set otherwise, the coordinate
displayed is that which corresponds
to the highest coordinate class
available.

Use the COORD (F2) key to switch
between Coordinate Systems.

Use the INFO (F5) key in the same
way as in the MANAGE screen to
switch the information displayed
about the point.

Additionally, when a Configuration Set
is being used where Advanced mode
is set, the averaging functionality in
Threshold Settings is set to Avg and
the point contains more than one
measurement, the AVRG (F6) key is
available.

Press USE (F2) to either select or
deselect measurements from the
averaged coordinate.

Press DEL (F4) to delete single
measurements.

When you have finished editing the
coordinates, press STORE (F1) to
store the point and return to the list of
points of the current job.