Leica Geosystems GPS System 500 - Technical Reference Manual User Manual

Page 96

Advertising
background image

96

5. Configuring the Receiver

Technical Reference Manual-4.0.0en

Logging
In addition to the functionality given in
Standard mode, you can also specify
the observables to be recorded and
access further functionality via the
FILES (F6) key.

Observables - Defines what is
recorded in the raw GPS data.
Extended records extra observables
including the Doppler observable.

Pressing the FILES (F6) key enables
you to configure further options.

Log File Segments - Will split up
the recorded data into files of a
specific time-based length unless 1
File
is selected. If a time is selected
the option Split Tracks will become
available. Select No will only record
data into a new file if the time is
reached and a new track is observed.

Auto Del Log Files - Will delete the
recorded data after the specified
length of time unless Never is se-
lected.

Press CONT (F1) to return to
CONFIGURE\Logging.

Occupation Settings
Additional functionality available in
this panel over Standard mode is
Auto OCUPY, Auto Stop, STOP P-
PRC
and END Survey.

Auto OCUPY - will automatically
occupy the point as soon as the
survey is started. Timed is chosen for
automatic point occupations at a
certain time. The time is specified in
the SURVEY panel.

Auto Stop - will automatically stop
the measurements according to the
setting in the STOP P-PRC function.
The measurements stop when the
criteria for the setting reach 100%.

Advertising