Using the telemax service – Leica Geosystems GPS System 500 - Technical Reference Manual User Manual

Page 359

Advertising
background image

359

Appendix H

Technical Reference Manual-4.0.0en

To make use of the Telemax service
you first have to transfer the sensor
specific Account file to your sensor. A
maximum of two Account files may
be transferred to each sensor, e.g.
one for private and one for non-
private use.
For details on how to transfer such
Account Files refer to chapter 13.15
Transfer Telemax Account File.

Configuration

In the CONFIGURE\ Interfaces panel
highlight Real-Time and press EDIT
(F3).

Set a R-Time Data to Rover and set
the Data Format to either RTCM 1,2
or RTCM 20,21.

Press DEVCE (F5) to access the
device list. Select the GSM or Modem
attached to your sensor from the list
or define a NEW (F2) one. For details
on how to configure and use a GSM
phone or Modem refer to the sub-
chapters GSM and Modem in the
Appendix H.

Press CONT (F1) to confirm your
selection and return to the CONFIG-
URE\ Real-Time panel.

Press the RTCM (F6) key to select
the Telemax service in setting
Telemax to YES. Select the appro-
priate Accountfile, which you have
transferred to the sensor before.

With the Data Format being set to
RTCM two different services are
available. Either RTCM corrections
from the closest reference can be
received or your own position can be
sent via the selected device which
then receives corrections based upon
a virtual reference station.

Change Ref Net to YES if corrections
for a virtual reference shall be used.

Press CONT (F1) to confirm.

Using the Telemax Service