Leica Geosystems GPS System 500 - Technical Reference Manual User Manual

Page 126

Advertising
background image

126

5. Configuring the Receiver

Technical Reference Manual-4.0.0en

Logging
In addition to the functionality given in
Standard mode, you can also specify
the observables to be recorded and
access further functionality via the
FILES (F6) key.

Observables - Defines what is
recorded in the raw GPS data.
Extended records extra observables
including the Doppler observable.

Pressing the FILES (F6) key enables
you to configure further options.

Log File Segments - Will split up the
recorded data into files of a specific
length unless 1 File is selected.
If a time is selected the option Split
Tracks
will become available. Select
No will only record data into a new file
if the time is reached and a new track
is observed.

Auto Del Log Files - Will delete the
recorded data after the specified
length of time unless Never is se-
lected.

Press CONT (F1) to return to
CONFIGURE\Logging.

Therefore, the time slots are at 0.00
sec and at 0.50 sec. With three
reference stations, the time delay is
0.33. The time slots are at 0.00, 0.33
and 0.66 sec.

The second Real-Time 2 interface is
completely independent to the Real-
Time 1 interface so that the number
of reference stations and time slots
can be configured differently.

Advertising