13. Transfer

Technical Reference Manual-4.0.0en

Press IFACE (F5) and set Use
Device
to YES.

Select the port to which the device is
connected. Use the DEVCE (F5) key
in the CONFIGURE\ GSI/User Out
panel to configure the device itself.

Leica TPS300/700, Geodimeter and
Zeiss REC500 total stations as well
as the SOKKIA SDR33 datalogger
are currently supported.

When Leica TPS300/700 is selected
and connected to the GPS receiver,
select the Job Number to which job
the data should be sent. The Job
Name
of existing jobs in the TPS
instrument is displayed. For a new
job, type in a name. When transfering
into an existing TPS job, all fixpoints
in that job are deleted during transfer.

If data is being transferred to a
Geodimeter total station, then the
total station must be in a mode ready
to receive data.

SOKKIA devices can only handle 4
digit numeric point IDs. If Renumber
is set to YES, all points are transfered
but renumbered starting from 1. If NO
is selected, only points with numeric
point IDs are transfered and point IDs
are shortened to 4 digits, truncating
from the right.

The SDR33 must be ready to receive
data before starting the transfer on
System500. Jobs are transfered with
the same name as on System500.

It is necessary to use the correct
format file when transferring data to a
total station.

Press FILT (F6) if you wish to transfer
a selection of points only. For more
information about the filter settings
please refer to 11.3 Point
Management.

Press CONT (F1) to transfer the file.
The number of exported points will
then be displayed.