5. Configuring the Receiver

Technical Reference Manual-4.0.0en

Threshold Settings

These settings are used as checks if
more than one set of measured
coordinates are recorded for the
same point.

Avg. Limits Pos - Only available if
Avg is selected. Sets the averaging
limit for position. When two or more
coordinates are recorded for the
same point, the system will compute
an average for the positions and
check that each position does not
differ from the average by more than
the defined amount. If they do differ
by more than the defined amount, you
will be alerted and can then decide
whether to raise the averaging limits
and record the coordinates or to
ignore the coordinates.

Avg. Limits Height. - Only available
if Avg is selected. Sets the averaging
limit for height. The system will
compute an average for the heights
and check that each height does not
differ from the average by more than
the defined amount. If they do differ
by more than the defined amount, you
will be alerted and can then decide
whether to raise the averaging limits
and record the coordinates or to
ignore the coordinates.

Avg/Abs Diffs - A check can either be
defined as an averaging functionality or
as an absolute coordinate difference
for X, Y, Z and E, N, H (with local
coordinate system). Avg is the default
option. When selecting Abs, the
average position is still calculated.

Regardless of whether Avg or Abs is
selected, points with more than one
associated measured point will still be
shown as average in Point
Management.

Monitor CQ - Allows to check the
quality (CQ) of a point before it is
stored. It is possible to choose to set
a Pos only, Height only, Pos +
Height
CQ limit or no limit at all
(None).

Quality - Sets the value for Monitor
CQ
.

Advertising